LANDMARK ELECTRONICS

LANDMARK ELECTRONICS
42,Jupitor Narendra park CHS Bldg,B-Wing,
Narendra Park,Mira Road East.
Mumbai, Maharashtra 401107
India

ph: 9869520508
alt: 9702336620

Smart Card Reader

 

  • CONTACT LESS SMART CARD READER  SAVIOR - 3000 SERIES

      

        3000    
    SLEEK, SMALL, RUGGED AND WORLD CLASS    
        
    THE IDEAL CHOICE FOR ALL ACCESS    
    CONTROL APPLICATIONS    
        
    FAVOURITE PICK OF ARCHITECTS    
        
    BEST BET OF BUILDERS    
        
    CRUCIAL FOR SYSTEM INTEGRATORS AND    
    APPLICATION DEVELOPERS    
        
    GREAT OPTION FOR OEMs    
        
    A BOON FOR RE-SELLERS    
        
    MUST FOR ALL WHO LOOK FOR A JUDICIOUS    
    BLEND OF TECHNOLOGY AND ECONOMY    

      

      3000 Series technical Specifications  

    © Technology- Mifare                                                                                    
    © Reading Distance - 50 mm     
    © Operation type - Read / Write- Customized.     
    © Cards Supported - 1 KB, 4 KB     
    © Read / Write Endurance for Card : Unlimited / 1 Lac Cycles     
    © 8 Digit Alphanumeric card number     
    © Display- Tri color LED visible from Front & Top     
    © Power on- Orange, Card OK - Green, Card not OK - Red     
    © Audio confirmation of card reading.     
    © Inbuilt Communication Interface : RS 232
    © Operating Voltage : DC 12V, 250mA
    © Power Consumption 3W ( max )
    © Baud Rate : 9600bps-N-8-1
    © Operating Temperature :- 05 C ~ 50 C
    © Relative Humidity : 20% ~ 95% ( Non Condensing )
    © Dimensions : 105 mm (L) x 90 mm (W) x 15 mm (D)
    © Weight of Reader :150 gms.
    © Enclosure : FR ( Fire Retardant ) Grde ABS


     

  • CONTACT LESS SMART CARD READER SAVIOR - 7000 SERIES

    7000
    © Technology - Milfare 
    © Reading Distance - 50 mm 
    © Operations type - Read / Write Reader 
    © Cards Supported - 1 KB. Optional - 4 KB, 4 KB     © Read / Write Endurance for Card : Unlimited / 1 Lac  cycles 
    © 8 Digit Alphanumeric card number. 
    © Display - LCD ( 16 characters x 2 rows ) alphanumeric 
    © LCD Displays DD-MON-YYYY, day of week and HH:MM:SS  time format.
    © LCD Displays employee name in English if name coded in the card. 
    © Greets card holder on Birthday ( if date coded in Card ) 
    © Audio / Visual confirmation of card reading. 
    © RTC : Leap year programmed 
    © Data Backup : Lithium Battery.  
    © Reasons Card Supported : For single ( OD, Leave etc. ) and 
    © Group Reasons ( Bus Late, etc.) 

     

     

    © Door Open Time ( If interface supports ): Up to 240 seconds
    © Continuous Beep : Incase Door Opened forcefully or kept
        Open for more than four seconds.
    © Emergency Fire Exit Option at Computer Level to Open
        all/Specific Doors.
    © Siren Setting - 24. Duration in steps of 5 secs upto 60 secs
    © Inbuilt Interface to External Parallel Printer.
    © Optional at extra cost - Siren Interface, Printer, Modem
        Customized Audio-Visual-Voice Activation.
    © Operating Voltage : DC 12V,500mA
    © Power Consumption 6W ( max )
    © Baud Rate for RS 232/RS 485 Communication : 9600bps-N-8-1
    © Operating Temperature :-05 C ~ 50 C
    © Relative Humidity : 20% ~ 95% ( Non condensing )
    © Dimensions : 115mm (L) x 107mm (W) x 50mm (D)
    © Weight of Reader : 300 gms.
    © Enclosure : Heavy Duty Plastic Body (HIPS)

  • Standard Application No. 02 - Access with EM Lock on Savior 7000 Series

    SA                                                               
  • SAVIOR Door Controller for Access Item code.: DC-1001-01

    © Supports two SAVIOR Readers OR one SAVIOR reader with exit push button.
    © Interface to deactivate EM Lock, in case input received from Fire Alarm Panel
    to Door controller. Input Voltage accepted from Fire Alarm Panel - 5 to 48 V DC
    © Supports one Single Door Electromagnetic Lock with Door Sensor.
    © Supports one Emergency Fire Switch.
    © Power supply for two readers and electromagnetic lock included.
    © Input Voltage : 100 to 270 Volts AC 50Hz
    © Internal Short circuit and over current protection provided.
    © Over and under voltage protection provided.

    SAVIOR Door Controller for Attendance Item code.: DC-1002-01 
     
    © Supports one SAVIOR reader 
    © Input Voltage : 100 to 270 Volts AC 50Hz. 
    © Internal Short Circuit and over current protection provided. 
    © Over and under voltage protection provided. 
     
     SAVIOR External Battery Backup Item Code.: BB-4001-01 
     
    © Supports one SAVIOR Readers OR one SAVIOR reader with exit push button. 
    © Supports one Single Door Electromagnetic Lock with Door Sensor. 
    © Input Voltage : 100 to 270 Volts AC 50Hz. 
    © Output Voltage : 12Volts DC 
    © Battery Backup : 4 Hours ( Based on usage ) 

    Customized Option : Anti Pass Back Facility. Requires Customized Reader at P & A to Reset Flags ( If Reqd.)

    Exit push button Item Code.: SW-01-01 *  Emergency Fire Switch Item Code.: SW-02-01
    Electro Magnetic Lock with Door Sensor ( Single Door ) Item Code.:EM-01-01
    Electro Magnetic Lock with Door Sensor ( Double Door ) Item Code.: EM-02-01

LANDMARK ELECTRONICS
42,Jupitor Narendra park CHS Bldg,B-Wing,
Narendra Park,Mira Road East.
Mumbai, Maharashtra 401107
India

ph: 9869520508